International Building Code Section 1105.1.8 is hereby amended to read as follows:

1105.1.8 Automatic doors. In facilities with the occupancies and building occupant loads indicated in Table 1105.1.8, all public entrances that are required to be accessible shall have one door be either a full power-operated door or a low-energy power-operated door. Where the public entrance includes a vestibule, at least one door into and one door out of the vestibule shall meet the requirements of this section.

Table 1105.1.8a

PUBLIC ENTRANCE WITH POWER-OPERATED DOORSa

OCCUPANCY

BUILDING OCCUPANT LOAD GREATER THAN

A-1, A-2, A-3, A-4

300

B, M, R-1

500

B – Medical Office Buildingb

10

I – Alcohol & Drug Treatment Centers

10

I – Assisted Living Facilities, Hospitals & Nursing Homes

Any

Footnotes:

aIn mixed-use facilities containing occupancies listed, when the total sum of the occupant load is greater than those listed, the most restrictive building occupant load shall apply.

bMedical Office Building shall include Ambulatory Care Facilities, Outpatient Clinics and facilities licensed by Washington State DSHS as Ambulatory Surgery Facility License or Medicare licensed Ambulatory Surgery Centers.

(Ord. 6531 § 5, 2020.)